Description
This is a NEW - unused Schneider Electric GV2P14 Motor Circuit Breaker 3 Pole 600V 6-10 Amp
Buyers and Re-sellers, don't miss this opportunity to purchase quality surplus equipment at a great price! There are many more surplus parts on our store, check it out!
Return Policy:
- Returns are accepted within 60 days of the delivery date. Rest assured we will cover all return shipping costs!
- All returns must be in "as shipped" original condition to qualify for a refund.
- Photos of packing and product is required for damaged items.
- Customer returns that satisfy all of the above requirements will be issued a refund including any applicable sales tax
Data sheet
Poles Description 3P Trip Unit Rating 6…10 A Trip Unit Technology Thermal-Magnetic Control Type Rotary Knob
Poles Description | 3P |
Trip Unit Rating | 6…10 A |
Trip Unit Technology | Thermal-Magnetic |
Control Type | Rotary Knob |
More info
Main range TeSys product name TeSys GV2 device short name GV2P product or component type Circuit breaker device application Motor trip unit technology Thermal-magnetic
Complementary poles description 3P network type AC utilisation category AC-3 conforming to IEC 60947-4-1
Category A conforming to IEC 60947-2 network frequency 50/60 Hz conforming to IEC 60947-4-1 fixing mode Clipped on 35 mm symmetrical DIN rail
Screwed on panel (with 2 x M4 screws) operating position Any position motor power kW 3 kW at 400/415 V AC 50/60 Hz
5 kW at 500 V AC 50/60 Hz
5.5 kW at 690 V AC 50/60 Hz breaking capacity 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 control type Rotary knob [In] rated current 6...10 A trip unit rating 6...10 A magnetic tripping current 138 A [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ith] conventional free air thermal current 10 A conforming to IEC 60947-4-1 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 power dissipation per pole 2.5 W mechanical durability 100000 cycles electrical durability 100000 cycles for AC-3 at 440 V operating rate 25 cyc/h rated duty Continuous conforming to IEC 60947-4-1 connections - terminals Screw clamp terminals 2 cable(s) 1...6 mm² solid
Screw clamp terminals 2 cable(s) 1.5...6 mm² flexible without cable end
Screw clamp terminals 2 cable(s) 1...4 mm² flexible with cable end tightening torque 1.7 N.m on screw clamp terminals suitability for isolation Yes conforming to IEC 60947-1 phase failure sensitivity Yes conforming to IEC 60947-4-1 height 89 mm width 45 mm depth 97 mm
Environment standards EN 60204
IEC 60947-1
IEC 60947-2
IEC 60947-4-1
NF C 63-120
NF C 63-650
NF C 79-130
UL 508
VDE 0113
VDE 0660
CSA C22.2 product certifications ATEX
BV
CCC
CSA
DNV
EZU
GL
LROS (Lloyds register of shipping)
RINA
TSE
UL
UL 508 type E
EAC protective treatment TH IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK04 ambient air temperature for operation -20...60 °C ambient air temperature for storage -40...80 °C fire resistance 960 °C conforming to IEC 60695-2-1 operating altitude 2000 m
range | TeSys | |
---|---|---|
product name | TeSys GV2 | |
device short name | GV2P | |
product or component type | Circuit breaker | |
device application | Motor | |
trip unit technology | Thermal-magnetic |
poles description | 3P | |
---|---|---|
network type | AC | |
utilisation category | AC-3 conforming to IEC 60947-4-1 Category A conforming to IEC 60947-2 | |
network frequency | 50/60 Hz conforming to IEC 60947-4-1 | |
fixing mode | Clipped on 35 mm symmetrical DIN rail Screwed on panel (with 2 x M4 screws) | |
operating position | Any position | |
motor power kW | 3 kW at 400/415 V AC 50/60 Hz 5 kW at 500 V AC 50/60 Hz 5.5 kW at 690 V AC 50/60 Hz | |
breaking capacity | 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
[Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
control type | Rotary knob | |
[In] rated current | 6...10 A | |
trip unit rating | 6...10 A | |
magnetic tripping current | 138 A | |
[Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
[Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
[Ith] conventional free air thermal current | 10 A conforming to IEC 60947-4-1 | |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 | |
power dissipation per pole | 2.5 W | |
mechanical durability | 100000 cycles | |
electrical durability | 100000 cycles for AC-3 at 440 V | |
operating rate | 25 cyc/h | |
rated duty | Continuous conforming to IEC 60947-4-1 | |
connections - terminals | Screw clamp terminals 2 cable(s) 1...6 mm² solid Screw clamp terminals 2 cable(s) 1.5...6 mm² flexible without cable end Screw clamp terminals 2 cable(s) 1...4 mm² flexible with cable end | |
tightening torque | 1.7 N.m on screw clamp terminals | |
suitability for isolation | Yes conforming to IEC 60947-1 | |
phase failure sensitivity | Yes conforming to IEC 60947-4-1 | |
height | 89 mm | |
width | 45 mm | |
depth | 97 mm |
standards | EN 60204 IEC 60947-1 IEC 60947-2 IEC 60947-4-1 NF C 63-120 NF C 63-650 NF C 79-130 UL 508 VDE 0113 VDE 0660 CSA C22.2 | |
---|---|---|
product certifications | ATEX BV CCC CSA DNV EZU GL LROS (Lloyds register of shipping) RINA TSE UL UL 508 type E EAC | |
protective treatment | TH | |
IP degree of protection | IP20 conforming to IEC 60529 | |
IK degree of protection | IK04 | |
ambient air temperature for operation | -20...60 °C | |
ambient air temperature for storage | -40...80 °C | |
fire resistance | 960 °C conforming to IEC 60695-2-1 | |
operating altitude | 2000 m |