Description
This is a NEW - unused Kele KCOC-W-A-A Carbon Monoxide Sensor With LED Indicator Wall Mount 4-20 mA
Buyers and Re-sellers, don't miss this opportunity to purchase quality surplus equipment at a great price! There are many more surplus parts on our store, check it out!
Return Policy:
-
Returns are accepted within 60 days of the delivery date. Rest assured we will cover all return shipping costs!
-
All returns must be in "as shipped" original condition to qualify for a refund.
-
Photos of packing and product is required for damaged items.
-
Customer returns that satisfy all of the above requirements will be issued a refund including any applicable sales tax
Supply Voltage: 18-28 VAC @ 2.5 VA, 50/60 Hz or 18-30 VDC @ 104 mA
VOC: 18-28 VAC @ 4 VA, 50/60 Hz or 18-30 VDC @ 166 mA
Accuracy:
CO: ±2.5% full scale
CO2: ±3% of reading or ±40 ppm
RH: 5% of reading 20% to 80% RH
VOC: ±10% ethanol equivalent
Signal Output: Analog 4-20 mA @ 600O, 0-10V
VOC: Stepped output (4, 12, 20 mA)
(0, 5, 10V)
Measurement Range:
CO: 0-200 ppm
CO2: 0-2000 ppm
RH: 0 to 100% RH
VOC: 0-1000 ppm ethanol equivalent
Sensing Technology:
CO: Electrochemical
CO2: Non-dispersive IR (NDIR)
RH: Capacitive
VOC: Sintered metal oxide
Visual Indication: LED Flashes above 20 ppm of CO. Display Optional, four-digit LCD
Warm Up Time: <15 minutes (maximum accuracy)
Relay Output: Optional, SPST 2A @ 24 VAC/VDC, closes >20 ppm
Alarm Auditory Levels Db: Optional, 65 dB, set at 20 ppm of CO
Operating Temperature: 32° to 122°F (0° to 50°C)
Operating Humidity: 0% to 99% RH (noncondensing)
Dimensions:
Wall: 4.5"H x 2.8"W x 1.0"D (11.4 x 7.3 x 2.54 cm)
Duct: 4.5"H x 2.8"W x 6.9"D (11.4 x 7.3 x 17.5 cm)
Duct Probe: 1.7" (4.3 cm) diameter, 6.25" (15.9 cm) long
Weight: Wall: 0.3 lb (0.14 Kg), Duct: 0.55 lb (0.25 Kg)
Application
Commerical Building, Industrial Site, Hospital, Mine, Aircraft
Measurement Range
0 - 200 ppm
Display
No
Output Signal
Current
- Combines CO sensor with CO2, RH, or VOC sensor
- LED status indication
- 0-10V or 4-20 mA output
- Optional relay output
- Isolated power and output
- Simple push button calibration
- Optional audible alarm
- Optional LCD display
Supply Voltage: 18-28 VAC @ 2.5 VA, 50/60 Hz or 18-30 VDC @ 104 mA
VOC: 18-28 VAC @ 4 VA, 50/60 Hz or 18-30 VDC @ 166 mA
Accuracy:
CO: ±2.5% full scale
CO2: ±3% of reading or ±40 ppm
RH: 5% of reading 20% to 80% RH
VOC: ±10% ethanol equivalent
Signal Output: Analog 4-20 mA @ 600O, 0-10V
VOC: Stepped output (4, 12, 20 mA)
(0, 5, 10V)
Measurement Range:
CO: 0-200 ppm
CO2: 0-2000 ppm
RH: 0 to 100% RH
VOC: 0-1000 ppm ethanol equivalent
Sensing Technology:
CO: Electrochemical
CO2: Non-dispersive IR (NDIR)
RH: Capacitive
VOC: Sintered metal oxide
Visual Indication: LED Flashes above 20 ppm of CO. Display Optional, four-digit LCD
Warm Up Time: <15 minutes (maximum accuracy)
Relay Output: Optional, SPST 2A @ 24 VAC/VDC, closes >20 ppm
Alarm Auditory Levels Db: Optional, 65 dB, set at 20 ppm of CO
Operating Temperature: 32° to 122°F (0° to 50°C)
Operating Humidity: 0% to 99% RH (noncondensing)
Dimensions:
Wall: 4.5"H x 2.8"W x 1.0"D (11.4 x 7.3 x 2.54 cm)
Duct: 4.5"H x 2.8"W x 6.9"D (11.4 x 7.3 x 17.5 cm)
Duct Probe: 1.7" (4.3 cm) diameter, 6.25" (15.9 cm) long
Weight: Wall: 0.3 lb (0.14 Kg), Duct: 0.55 lb (0.25 Kg)
Application
Commerical Building, Industrial Site, Hospital, Mine, Aircraft
Measurement Range
0 - 200 ppm
Display
No
Output Signal
Current
- Combines CO sensor with CO2, RH, or VOC sensor
- LED status indication
- 0-10V or 4-20 mA output
- Optional relay output
- Isolated power and output
- Simple push button calibration
- Optional audible alarm
- Optional LCD display