Phoenix Contact 2907161 UPS Power Supply 24 VDC 10 Amp

Phoenix Contact

MPN:
2907161
$470.59
$198.88
You save $271.71
UPC:
4055626166582
SKU:
0005512-PRK
$470.59
$198.88
You save $271.71

Description

This is a NEW - unused Phoenix Contact 2907161 UPS Power Supply 24 VDC 10 Amp

Buyers and Re-sellers, don't miss this opportunity to purchase quality surplus equipment at a great price! There are many more surplus parts on our store, check it out!

Return Policy:

  • Returns are accepted within 60 days of the delivery date. Rest assured we will cover all return shipping costs!
  • All returns must be in "as shipped" original condition to qualify for a refund.
  • Photos of packing and product is required for damaged items.
  • Customer returns that satisfy all of the above requirements will be issued a refund including any applicable sales tax

Features

  • Startup from energy storage possible, even without mains input
  • USB interface for connection to higher-level controllers such as industrial PCs
  • Long buffer times, thanks to large selection of VRLA energy storage systems
  • Space saving: Combination of UPS module and power supply in the same housing
  • Easy installation, thanks to push-in connection technology
  • Universal range of possible applications, thanks to a comprehensive package of approvals and an extended temperature range

Tech Specifications

Width68 mm
Height130 mm
Depth160 mm
Width with alternative assembly160 mm
Height with alternative assembly130 mm
Depth with alternative assembly68 mm
Degree of protectionIP20
Ambient temperature (operation)-25 ?C ... 70 ?C (> 60 ?C Derating: 2.5 %/K)
Ambient temperature (start-up type tested)-40 ?C
Ambient temperature (storage/transport)-40 ?C ... 85 ?C
Max. permissible relative humidity (operation)? 93 % (At +25?C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2
Installation height? 4000 m (> 2000 m, observe derating)
AC input voltage range100 V AC ... 240 V AC -15 % ... +10 %
Inrush current limiting/I?t< 0.2 A2s
Mains buffering time? 25 ms (120 V AC)
Typical response time200 ms
Input fuse, integrated6.3 A (slow-blow, internal)
Nominal output voltage24 V DC
Setting range of the output voltage (U<sub>Set</sub>)24 V DC ... 28 V DC (> 24 V constant capacity)
Nominal output current (I<sub>N</sub>)10 A
Dynamic Boost (I<sub>Dyn.Boost</sub>)15 A
Derating> 60 ?C (2.5%/K of POut nom.)
Control deviation< 0.55 % (Static load change 10 % ... 90 %)
Maximum power dissipation in no-load condition< 3 W (230 V AC)
Efficiencytyp. 90 % (120 V AC)
Efficiencytyp. 91 % (230 V AC)
Efficiencytyp. 96 % (Battery operation)
Residual ripple< 20 mV
Connection in parallelyes, with diode module uncoupled
Surge protection against internal surge voltages< 30 V DC
Feedback voltage resistance? 35 V DC
Net weight1.34 kg
Insulation voltage input/output4 kV AC (type test)
Insulation voltage input/output2 kV AC (routine test)
Protection classI
MTBF (IEC 61709, SN 29500)> 2007013 h (230 V AC, at 25 ?C)
MTBF (IEC 61709, SN 29500)> 1210518 h (230 V AC, at 40 ?C)
MTBF (IEC 61709, SN 29500)> 575978 h (230 V AC, at 60 ?C)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: horizontally 0 mm, vertically 50 mm
Connection methodPush-in connection
Conductor cross section solid min.0.2 mm?
Conductor cross section solid max.4 mm?
Conductor cross section flexible min.0.2 mm?
Conductor cross section flexible max.2.5 mm?
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length10 mm
Connection methodPush-in connection
Conductor cross section solid min.0.2 mm?
Conductor cross section solid max.4 mm?
Conductor cross section flexible min.0.2 mm?
Conductor cross section flexible max.2.5 mm?
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length10 mm
Connection methodPush-in connection
Conductor cross section solid min.0.2 mm?
Conductor cross section solid max.1.5 mm?
Conductor cross section flexible min.0.2 mm?
Conductor cross section flexible max.1.5 mm?
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm
Charge characteristic curveIU0U
Charge current0.2 A ... 3 A (-25 ?C ... 60 ?C)
EMC requirements for noise immunityEN 61000-6-1
EMC requirements for noise immunityEN 61000-6-2
EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise emissionEN 61000-6-4
Standard - safety for equipment for measurement, control, and laboratory useIEC 61010-1
Standard ? Safety extra-low voltageIEC 61010 (SELV) / (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard - power supply devices for low voltage with DC outputEN 61204-3
UL approvalsUL Listed UL 61010
UL approvalsUL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Conducted noise emissionEN 61000-6-3 (Class B)
Noise emissionEN 61000-6-3 (Class B)
DNV GL conducted interferenceClass B
Additional textArea power distribution
DNV GL noise radiationClass B
Additional textBridge and deck area
Electrostatic dischargeEN 61000-4-2
Contact discharge6 kV (Test Level 4)
Discharge in air8 kV (Test Level 4)
Electromagnetic HF fieldEN 61000-4-3
Frequency range80 MHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A
Fast transients (burst)EN 61000-4-4
Input4 kV (Test Level 4 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal2 kV (Test Level 4 - asymmetrical)
CommentsCriterion A
Input2 kV (Test Level 3 - symmetrical)
Input4 kV (Test Level 4 - asymmetrical)
Output1 kV (Test Level 1 - symmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal1 kV (Test Level 2 - asymmetrical)
CommentsCriterion A
Conducted interferenceEN 61000-4-6
I/O/Sasymmetrical
Frequency range0.15 MHz ... 80 MHz
Voltage10 V (Test Level 3)
CommentsCriterion A
Attenuated sinusoidal oscillations (ring wave)EN 61000-4-12
CommentsCriterion A
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
REACh SVHCLead 7439-92-1
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom50 mm / 50 mm
Inflammability class in acc. with UL 94 (housing / terminal blocks)V0
Inrush current limiting/I²t< 0.2 A2s
Standard – Safety extra-low voltageIEC 61010 (SELV) / (PELV)
Surge voltage load (surge)EN 61000-4-5

Extra Information

Brand:
Phoenix Contact
Weight:
0.06 LBS