Description
This is a NEW - unused Phoenix Contact 2907161 UPS Power Supply 24 VDC 10 Amp
Buyers and Re-sellers, don't miss this opportunity to purchase quality surplus equipment at a great price! There are many more surplus parts on our store, check it out!
Return Policy:
- Returns are accepted within 60 days of the delivery date. Rest assured we will cover all return shipping costs!
- All returns must be in "as shipped" original condition to qualify for a refund.
- Photos of packing and product is required for damaged items.
- Customer returns that satisfy all of the above requirements will be issued a refund including any applicable sales tax
Features
- Startup from energy storage possible, even without mains input
- USB interface for connection to higher-level controllers such as industrial PCs
- Long buffer times, thanks to large selection of VRLA energy storage systems
- Space saving: Combination of UPS module and power supply in the same housing
- Easy installation, thanks to push-in connection technology
- Universal range of possible applications, thanks to a comprehensive package of approvals and an extended temperature range
- Startup from energy storage possible, even without mains input
- USB interface for connection to higher-level controllers such as industrial PCs
- Long buffer times, thanks to large selection of VRLA energy storage systems
- Space saving: Combination of UPS module and power supply in the same housing
- Easy installation, thanks to push-in connection technology
- Universal range of possible applications, thanks to a comprehensive package of approvals and an extended temperature range
Tech Specifications
Width | 68 mm |
Height | 130 mm |
Depth | 160 mm |
Width with alternative assembly | 160 mm |
Height with alternative assembly | 130 mm |
Depth with alternative assembly | 68 mm |
Degree of protection | IP20 |
Ambient temperature (operation) | -25 ?C ... 70 ?C (> 60 ?C Derating: 2.5 %/K) |
Ambient temperature (start-up type tested) | -40 ?C |
Ambient temperature (storage/transport) | -40 ?C ... 85 ?C |
Max. permissible relative humidity (operation) | ? 93 % (At +25?C, non-condensing) |
Climatic class | 3K3 (in acc. with EN 60721) |
Degree of pollution | 2 |
Installation height | ? 4000 m (> 2000 m, observe derating) |
AC input voltage range | 100 V AC ... 240 V AC -15 % ... +10 % |
Inrush current limiting/I?t | < 0.2 A2s |
Mains buffering time | ? 25 ms (120 V AC) |
Typical response time | 200 ms |
Input fuse, integrated | 6.3 A (slow-blow, internal) |
Nominal output voltage | 24 V DC |
Setting range of the output voltage (U<sub>Set</sub>) | 24 V DC ... 28 V DC (> 24 V constant capacity) |
Nominal output current (I<sub>N</sub>) | 10 A |
Dynamic Boost (I<sub>Dyn.Boost</sub>) | 15 A |
Derating | > 60 ?C (2.5%/K of POut nom.) |
Control deviation | < 0.55 % (Static load change 10 % ... 90 %) |
Maximum power dissipation in no-load condition | < 3 W (230 V AC) |
Efficiency | typ. 90 % (120 V AC) |
Efficiency | typ. 91 % (230 V AC) |
Efficiency | typ. 96 % (Battery operation) |
Residual ripple | < 20 mV |
Connection in parallel | yes, with diode module uncoupled |
Surge protection against internal surge voltages | < 30 V DC |
Feedback voltage resistance | ? 35 V DC |
Net weight | 1.34 kg |
Insulation voltage input/output | 4 kV AC (type test) |
Insulation voltage input/output | 2 kV AC (routine test) |
Protection class | I |
MTBF (IEC 61709, SN 29500) | > 2007013 h (230 V AC, at 25 ?C) |
MTBF (IEC 61709, SN 29500) | > 1210518 h (230 V AC, at 40 ?C) |
MTBF (IEC 61709, SN 29500) | > 575978 h (230 V AC, at 60 ?C) |
Mounting position | horizontal DIN rail NS 35, EN 60715 |
Assembly instructions | alignable: horizontally 0 mm, vertically 50 mm |
Connection method | Push-in connection |
Conductor cross section solid min. | 0.2 mm? |
Conductor cross section solid max. | 4 mm? |
Conductor cross section flexible min. | 0.2 mm? |
Conductor cross section flexible max. | 2.5 mm? |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 10 mm |
Connection method | Push-in connection |
Conductor cross section solid min. | 0.2 mm? |
Conductor cross section solid max. | 4 mm? |
Conductor cross section flexible min. | 0.2 mm? |
Conductor cross section flexible max. | 2.5 mm? |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 10 mm |
Connection method | Push-in connection |
Conductor cross section solid min. | 0.2 mm? |
Conductor cross section solid max. | 1.5 mm? |
Conductor cross section flexible min. | 0.2 mm? |
Conductor cross section flexible max. | 1.5 mm? |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Charge characteristic curve | IU0U |
Charge current | 0.2 A ... 3 A (-25 ?C ... 60 ?C) |
EMC requirements for noise immunity | EN 61000-6-1 |
EMC requirements for noise immunity | EN 61000-6-2 |
EMC requirements for noise emission | EN 61000-6-3 |
EMC requirements for noise emission | EN 61000-6-4 |
Standard - safety for equipment for measurement, control, and laboratory use | IEC 61010-1 |
Standard ? Safety extra-low voltage | IEC 61010 (SELV) / (PELV) |
Standard - Safe isolation | DIN VDE 0100-410 |
Standard - power supply devices for low voltage with DC output | EN 61204-3 |
UL approvals | UL Listed UL 61010 |
UL approvals | UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
Conducted noise emission | EN 61000-6-3 (Class B) |
Noise emission | EN 61000-6-3 (Class B) |
DNV GL conducted interference | Class B |
Additional text | Area power distribution |
DNV GL noise radiation | Class B |
Additional text | Bridge and deck area |
Electrostatic discharge | EN 61000-4-2 |
Contact discharge | 6 kV (Test Level 4) |
Discharge in air | 8 kV (Test Level 4) |
Electromagnetic HF field | EN 61000-4-3 |
Frequency range | 80 MHz ... 6 GHz |
Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A |
Fast transients (burst) | EN 61000-4-4 |
Input | 4 kV (Test Level 4 - asymmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) |
Signal | 2 kV (Test Level 4 - asymmetrical) |
Comments | Criterion A |
Input | 2 kV (Test Level 3 - symmetrical) |
Input | 4 kV (Test Level 4 - asymmetrical) |
Output | 1 kV (Test Level 1 - symmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) |
Signal | 1 kV (Test Level 2 - asymmetrical) |
Comments | Criterion A |
Conducted interference | EN 61000-4-6 |
I/O/S | asymmetrical |
Frequency range | 0.15 MHz ... 80 MHz |
Voltage | 10 V (Test Level 3) |
Comments | Criterion A |
Attenuated sinusoidal oscillations (ring wave) | EN 61000-4-12 |
Comments | Criterion A |
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
REACh SVHC | Lead 7439-92-1 |
Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 50 mm / 50 mm |
Inflammability class in acc. with UL 94 (housing / terminal blocks) | V0 |
Inrush current limiting/I²t | < 0.2 A2s |
Standard – Safety extra-low voltage | IEC 61010 (SELV) / (PELV) |
Surge voltage load (surge) | EN 61000-4-5 |